SOYAL TECHNOLOGY CO., LTD

Membership Center
0
Browsing Records
How to read card information from one controller?
2020-12-24
No. S00305009-EN

Serial NO.: S00305009-EN

Date of Editing: 2011-07-08

Answer:

1.    Execute 701Client and select “user”   
2.    Select “tools box” and then click “Read/Write to 701H”

2.
A: Controller reader connects to AR-716E. You have to select the node id for AR-716E first and then select node id for controller reader. Please follow the step as below:
 
For example, AR-716E(node id 3) and AR-721H(node id 2)
1.    Execute 701Client and then select “user”
2.    Select “tools box” and then click “Read/Write to 701H”
3.    Select “721/727H V3(V5.5) Under 716Ex”
4.    Set controller node id ”003” and reader node id “02”
5.    Access range please select “Read”
6.    Click “Start”



B. Only controller reader connects to PC. Please select node id for controller reader and then start to read.

1.    Execute 701Client and then select “user”
2.    Select “tools box” and then click “Read/Write to 701H”
3.    Select “721/727H V3(V5.5) Under PC”
4.    Set controller node id ”002”
5.    Access range please select “Read”
6.    Click “Start”

 

 

Related Tag