Serial NO. : H00101002-EN
Date of Editing : 2023-02-10
Questions : How to set up H/E series controllers to keep the door open after swiping the card and only close it after the second swipe?
Answer :
The H/E series controllers have a door lock relay time setting function. When the parameter time is set to 0, the door lock relay will continuously output, keeping the electronic lock in an open state until the second card is sensed to stop the output of the door open signal. The setup method is as follows:
H series controller:
Parameter setting: Enter editing mode (default value *123456#) > 02*000# > press *# to exit editing mode.
E series controller with LCD screen (e.g.AR-837E/ER/EF/EA, AR-727E):
Parameter setting: enter editing mode (default value *123456#) > 3. Parameters [1] > 3. Door Relay Tm > Set as 000
E series controller with keypad only (AR-725E):
Parameter setting: enter editing mode (default value *123456#) > 02*0*000# > press *# to exit editing mode.