Questions :  How to set up floor control on AR-721H and how to connect it?

Problem Solving :

 

1. Function setting:

After enter edit mode, input command  2   4   *   0   0   2   #   to set up

[Alarm output] as [Series output].

2. Wiring:

Connector P1 Grey wire【Series output】 to AR-829L485 yellow wire. You should supply the controller and AR-829L485 with the same power.

3. Single-floor setting:

    2   7   *   0   0   0   0   1   *   3   1   #

                                    User Address                  Floor

      Multi-floor setting:

     

                   User Address                                  Group                                       Floor setting

Floor setting definition

0: Enable floor

1: Disable floor

According to the following table, this user can reach floor 8/ 7/ 2/ 1

※Input  2   3   *  to change AR-401RO16 relay time, which will provide enough time for user to press floor button in the elevator. Please refer 401RO16 user manual for detailed information.

 