How to set virtual Door - H/ Door - L for AR-723HD by protocol?
2021-03-08
No. S00901005-EN

Serial NO : S00901005-EN

Date of Editing :  2011-10-26

Questions : How to set virtual Door - H/ Door - L for AR-723HD by protocol? 

Problem Solving :

  1. Please use CommView  to input command to set virtual Door-H and Door-L

For example, to set virtual door-H as 3 and door-L as 7 for Node ID 3 controller. The door release time as 5000ms(default value)

80    Command

03    Node

44    D-ASCII = 44 (fixed value)

03    Door-H      Virtual Node ID

07    Door-L      Virtual Door Num

01    TT-h        Door release time for example: 5 seconds = 500x10ms 500à 01F4 ( Unit:10ms)

F4    TT-L        Door release time for example: 5 seconds = 500x10ms 500à 01F4 ( Unit:10ms)

4D    M-ASCII = 4D (fixed value)

00    UID-2       (fixed value 00)

00    UID-1       (fixed value 00)

07    UID-0       (01 ~ 254) hex

 Execute 701Client and then click to edit door name:

You can click [Setting] and then click [System Parameter Setting]

If you check the [Enable Huge-Door-Group Mode], the transaction record will show Node ID, virtual node ID and door name. If you don’t check this option, it will show door name only.

The transaction record is as below