Serial NO. : H00107011-EN
Date of Editing : 20181-10-17
Questions : Could give instruction to enable "Door Open Too Long" for AR-721-H?
Problem Solving :
1. Please enable arming first (refer to Remark of it's setting in the document)
2. Set the time you want or you can apply in default value.
Remark:
Door relay time: to set how long the door relay (lock release) is active for after showing a card.
Door close time: sets how long the door contact can remain open for before activating the alarm.
Alarm delay time: to delay the activation of the alarm relay after an alarm condition has arisen, so that user can have enough time to disable alarm.
Alarm relay time: when an alarm condition has arisen, the alarm will activate for the duration.
Arming delay time: to delay the time of enabling arming, so that user can have enough time to disable arming.
Compare list as below,
Remark: Arming status setting:
1. In 721H/757H command: **#
2. In 727H/747H/829E/821EF screen list : 7. Quit & arming
721H/757H default status of normal access: