Answer:

You need to set up AR-829E and 701Client to this function at, instructions are described as below:
1.    Please login 701Server first, then click “829” icon at tool bar. After read   
      parameter from AR-829E, enable “Auto Open(Zone:63)” function at
      “821E/829E Parameter setting” window, then click “Write To Controller”
      button to complete 701Server setting.

2.    After login 701Client, click “Zone” icon at tool bar, Edit Start time, End time at Zone 63, set Level to 00 and Link to End.

3.    Click “Download” icon at tool bar, then click “Time Zone” button to download time zone data to controller.

4.    You will see “Enter Auto Door Open Procedure” message in transaction record as below figure.