SOYAL TECHNOLOGY CO., LTD

Membership Center
0
Browsing Records
How to wire AR-725-E with lift control AR-401-IO-0016R?
2021-06-24
No. H02401001-EN

Serial NO. : H02401001-EN

Date of Editing : 2017-08-31

Questions :  How to wire AR-725-E with lift control  AR-401-IO-0016R?

Problem Solving :

The equipment and accessories you need

  • No. 1: the wire P3 (together with AR-725-E)

  • No. 2: AR-725-E (IP controller)
  • No. 3: AR-401-IO-0016R (Lift module)
  • No. 4: AR-MDL-RJ45 (Connector with RJ45 socket for TCP/IP wiring)
  • No. 5: AR-725L485 (TTL/RS-485 Converter)
  • No. 6: the wire P4 (together with AR-725-E)

There are 3 wiring methods depending on your site condition; the connection 3 is the recommended method.

 

  • Connection 1:

No. 4 AR-MDL-RJ45 connect to AR-725-E

No. 6 the wire P4 connect to lift module No. 3  AR-401-IO-0016R

  • Connection 2:

No. 6 the wire P4 connect to AR-725-E

No. 5 AR-725L485 connect to lift module No. 3  AR-401-IO-0016R

 

  • Connection 3:

No. 4 AR-MDL-RJ45 connect to AR-725-E

No. 5 AR-725L485 connect to lift module No. 3  AR-401-IO-0016R

 

 

Browsing Records