How to wire AR-725-E with lift control AR-401-IO-0016R?
Serial NO. : H02401001-EN
Date of Editing : 2017-08-31
Questions : How to wire AR-725-E with lift control AR-401-IO-0016R?
Problem Solving :
The equipment and accessories you need
- No. 1: the wire P3 (together with AR-725-E)

- No. 2: AR-725-E (IP controller)
- No. 3: AR-401-IO-0016R (Lift module)
- No. 4: AR-MDL-RJ45 (Connector with RJ45 socket for TCP/IP wiring)
- No. 5: AR-725L485 (TTL/RS-485 Converter)
- No. 6: the wire P4 (together with AR-725-E)


There are 3 wiring methods depending on your site condition; the connection 3 is the recommended method.
- Connection 1:
No. 4 AR-MDL-RJ45 connect to AR-725-E
No. 6 the wire P4 connect to lift module No. 3 AR-401-IO-0016R


- Connection 2:
No. 6 the wire P4 connect to AR-725-E
No. 5 AR-725L485 connect to lift module No. 3 AR-401-IO-0016R


- Connection 3:
No. 4 AR-MDL-RJ45 connect to AR-725-E
No. 5 AR-725L485 connect to lift module No. 3 AR-401-IO-0016R