How to set Auto open door function on 829EV5/821EV5/881E/725EV2 series reader?
2020-12-21
No. S00205004-EN

Serial NO.: S00205004-EN

Date of Editing: 2012-09-17

Answer:

Software Support:"701 Server&701Client "Version 8.01 after
Case: The door should be open automatically at 3 set of time zone: 08:00~10:00, 12:00~14:00, 17:00~19:00 from Monday to Sunday
Click “881/821EV5”icon on menu bar to enter “parameter setting” figure
1.    Click “Read” to read parameter from reader
2.    Tick option “Enable Free Zone”
If you would like that the door can open without presenting first card, please tick option” Free Zone Open Imm”
If you would like that the door can open with presenting first card, please don’t tick option “Free Zone Open Imm”
3.    Click “Free Zone” to enter “Free zone Editor” figure
4.    The system support up to 16 set of free zone ,  for this case, pls tick Sun to Mon, put 3 set of free zone time : 08:00~10:00, 12:00~14:00, 17:00~19:00 , select :Main” and tick , click "Ok" to quit
5.    Finally click “Write” to write new parameter to reader