Serial NO. : S0020201-EN
Date of Editing : 2022-01-19
Problem Solving :
Content
(Tick to jump directly to the content)
1. How to choose the model option for the 701ServerSQL LAN based?
2. How to distinguish whether a controller of the same model is from the H series or E series?
How to choose the model option for the 701ServerSQL LAN based?
No. | LAN Model No. 10.2 version and before | LAN Model No. 10.2 version and after | Correspondent Hardware Model No. | Communication Interface | Port | Active Communication Mode (Non-Polling) | |
1. | Modbus_TCP | Modbus_TCP | PLC Modbus TCP | Modbus | 502 | ||
2. | TCP_IO | TCP_IO | IP Based I/O Module - AR-727-CM-IO- 0804M | TCP/IP | 1601 | YES (required additional setting of Message Server IP point to 701ServerSQL's Local TCP Link Address & TCP Port) | |
3. | RS485_IO | RS485_IO | RS485 I/O Module - AR-401-IO-0016R | RS485 (via AR-321-CM converter) | 1601 | X | |
4. | 881/837/331E&EF /82xEv5/721 /725Ev2/727/327Hv5 | 327E/3xxE/ 7xxE/8xxE/716Ev5 | All Enterprise Series Controller (E Series) - AR-725-E Control Panel -AR-716-E16 Enterprise Series Controller(Old Version) - AR-881-EF | TCP/IP (if onboard TCP/IP module) | 1621 | YES (required additional setting of Message Server IP point to 701ServerSQL's Local TCP Link Address & TCP Port) | |
TCP/IP (via AR-727-CM converter) | CH1 1621 CH2 1623 | X | |||||
RS485 (via AR-321-CM converter) | X | ||||||
5. | 721E_1024 | 721E_1024 | Dual WG control panel - AR-716-E02 | RS485 (via AR-321-CM converter) | X | ||
6. | 3K 321/331/ 725/888H | 3K 321/331/ 725/888H | Home Series (H Series) controller that support 3000 user interface - AR-321H | TCP/IP (via AR-727-CM converter) | CH1 1621 CH2 1623 | X | |
RS485 (via AR-321-CM converter) | X | ||||||
7. | 821EV | 821EV | Controller
| TCP/IP (via AR-727-CM converter) | CH1 1621 CH2 1623 | X | |
RS485 (via AR-321-CM converter) | X | ||||||
8. | 821EF V9 | 821EF V9 | Controller
| TCP/IP (via AR-727-CM converter) | CH1 1621 CH2 1623 | X | |
RS485 (via AR-321-CM converter) | X | ||||||
9. | 716E V3/Ei | 716E V3/Ei | Control Panel - AR-716-E18 | TCP/IP | 1621 | ||
RS485 | X | ||||||
10. | 829E V3 | 829E V3 | Controller
| RS485 (via AR-321-CM converter) | X | ||
11. | 727/747 H V3 | 727/747 H V3 | Controller | RS485 (via AR-321-CM converter) | X | ||
12. | 323D/321&888W/721 /757/737/723/101H V3 | 101H/323D/321&888W /721/723/757 | Home Series (H Series) controller that support 1000 user interface - AR-101-H Controller (Old version) | TCP/IP (via AR-727-CM converter) | CH1 1621 CH2 1623 | X | |
RS485 (via AR-321-CM converter) | X | ||||||
13. | 829E Old | 829E Old | Controller (Old version)
| RS485 (via AR-321-CM converter) | X |
Note : Active Communication Mode (Non-Polling) only available for Enterprise Series (E Series) Controller and Control Panel AR-716-E16 with TCP/IP Module on-board
More detail about implementing Active Communication Mode --> Here
How to distinguish whether a controller of the same model is from the H series or E series?
* If the model no. could not be identified, please refer to the following instruction:
Sound of H series Controller | Sound of E series Controller |
Sound of H series Controller | Sound of E series Controller |