Serial NO.: H03506002-EN
Date of Editing: 2022-08-09
Ans:
The reason is that the Controller is in arming status, there are three situations will trigger the arming status :
1. Door open too long: The door is open longer than door relay time plus door close time.
2. Force open: The door has been opened without a valid card or PIN, accessing by force or illegal procedure.
3. Abnormal door position: Arming is enabled and the power is suddenly off then on.
※ Note: Controllers are all enabled Arming Function for default value, it can be closed by customer demand.
Solution:
Method 1: Disable Arming Status
| Picture |
| ||
| Function | Without enter program mode | Card Only | After door open : present valid card -> input 4-digit arming code ->![]() |
Door closed : --> Input 4-digit arming code -> present valid card | |||
| Card or PIN | Input 5/6-digit user address -> input 4-digit personal PIN -> -> Input 4-digit arming code ->![]() | ||
| Card and PIN | Present valid card -> input 4-digit personal PIN -> -> Input 4-digit arming code ->![]() | ||
| Enter program mode | Press to exit the programming mode(disable arming in the meanwhile) | ||
| ※ Default value of arming PIN : 1234 | |||
| Picture |
| |
| Function | Without enter program mode | Open door and enable/disable arming : normal door open procedure -> input 4-digit arming code -> |
Enable/disable arming without door open: -> Input 4-digit arming code -> present valid card | ||
| Enter program mode | Enter Programing Mode -> ![]() ![]() | |
| ※ Default value of arming PIN : 1234 | ||
| Picture |
| ||
| Function | Without enter program mode | Card Only | Disable all devices : present valid card -> input 4-digit arming code -> ![]() ![]() ![]() |
Disable particular device : present valid card -> input 4-digit arming code -> U or ![]() | |||
| Card or PIN | Input 5-digit user address -> input 4-digit personal PIN -> -->input 4-digit arming code -->![]() or U![]() | ||
| Card and PIN | Present valid card -> input 4-digit personal PIN--> --> input 4-digit arming code → 9 or U![]() | ||
| ※ Default value of arming PIN : 1234 (U=Reader unit (0=AR-725-E, 1=WG Reader). | |||
Method 2 : Wiring the orange line(Door Sensor) to GND
After the Door Sensor connect to GND, the function will be disabled and the alarm will not be trigger.