Questions: Smart electronic mailbox application, settings and precautions
Introduce:
The AR-1213P locker can be integrated with an electronic mailbox or parcel locker using the E series controller and RS485 communication module (AR-401-IO-0016R), supporting up to 256 units and can be paired with a voice module to provide voice prompts.
Setting precautions:
※ The electric lock time of the controller needs to be set below 0.5 seconds to avoid long-term triggering of the power switch, causing excessive heating of the coil and damage.
E-series screen controller:
Setting method: Enter editing mode (default value *123456#) > 5. Tools > 0. UART Port CN9 > 0: Lift9600 > Set card-swiping waiting time range.
Relay time:
000 = Continuous output switching mode
001~ 600 = 1 second ~ 600 seconds
601~ 609 = 0.1 second ~ 0.9 second.
E-Series touch-type controller:
Set the relay time through the floor control action time (M4/M8) command
Setting method: enter the edit mode (default value 123456#) > 23*MMM*TTT#
MMM=Node ID of lift controller
TTT=relay time
000 = Continuous output switching mode
001~ 600 = 1 second ~ 600 seconds
601~ 609 = 0.1 second ~ 0.9 second.
RS485 communication output module 401-IO-0016R dial setting:
Transmission rate (BAUD9600), N.C. TYPE elevator floor dedicated
N.C./N.O. Type witch
SW8: When the dial is set to OFF, it is in N.O. mode (used in mailboxes)
When the power is turned on, the device or equipment connected to it will be in the open state
SW8: When the dial is set to ON, it is in N.C. mode (used in elevators)
When the power is turned on, the device or equipment connected to it will be in the closed state.