Low in cost, efficient, and quick monitoring over all hotel rooms monitoring with 701ClientSQL Graphic Animation. The application will be able to monitor which room has customer inside room, room required room service, do not disturb, and emergency button notification.
Example below is three floors hotel with total 12 rooms to manage.
Configuration and I/O Mapping Table
Example: 12 rooms hotel management setting | ||||||||
Device | Node ID | Device Type | I/O Type | I/O Num | ||||
AR-323D-V2 (12 units) | 1~12 | |||||||
AR-888-W (12 units) | 13~25 | |||||||
403-IO-0404M (12 units) | 26~37 (Room 101 node ID 26 | Digital I/O | DIO State | DI0 Insert card holder (AR-888-W): 0 | ||||
Digital I/O | DIO State | DI1 Do Not Disturb (AR-888-CPI): 1 | ||||||
Digital I/O | DIO State | DI2 Clean Room (AR-888-CPI): 2 | ||||||
Digital I/O | DIO State | DI3 Emergency Button (AR-PB2): 3 |
701ServerSQL Setting: Access Point Setting
Area | Area00 | |||
Node ID | Device selection | IP | IP Address | Port |
1~6 | 323D/321/888W/721/757/737/723 | V | 192.168.1.171 | 1621 |
7~12 | 323D/321/888W/721/757/737/723 | V | 192.168.1.171 | 1623 |
13~25 | 323D/321/888W/721/757/737/723 | V | 192.168.1.172 | 1621 |
26~37 | RS485_IO | V | 192.168.1.172 | 1623 |