Serial NO. : H02417002-EN
Date of Editing : 2010-07-16
Questions : How the AR-725E and its two WG readers to control single door?
Problem Solving :
You can use AR-725E and its two WG readers share main relay to control single door. The diagrams below show how the AR-725E connects to its two WG readers:
AR-725E and AR-725E's WG access reader how to control the same door
1. Access programming mode
2. 24*U*016#
2-1 U: WG access reader
2-1-1 U: 1(WGA)
2-1-2 U: 2(WGB)
3. Quit programming mode
Cancel AR-725E and AR-725E's WG access reader to control the same door
1.Access programming mode
2. 24*U*000#
2-1 U: WG access reader
2-1-1 U: 1(WGA)
2-1-2 U: 2(WGB)
3. Quit programming mode