SOYAL TECHNOLOGY CO., LTD

Membership Center
0
Browsing Records
701Software, Enterprise Series (E Series) Controller and Home (H Series) Series Controller Full Command Table
2022-08-19
No. I005027-EN

Serial NO : I005027-EN

Date of Editing : 2022-08-19

Answer:

Note 1:   ※  : Function noted with※ means that it is new updated. For Enterprise E series controller, the firmware version that support above functions should be released after 2022 April 19th; For Home H series controller, the firmware version should be released after 2022.

Note 2 :  20*/24*/28*/34* are multiple commands, please refer to "Function Default Value" Chapter to ensure the command.

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Enter the Program Mode *PPPPPP# 
PPPPPP:Master Code,Default Value:123456
 *PPPPPP# 
PPPPPP:Master Code,Default Value:123456
 *PPPPPP# 
PPPPPP:Master Code,Default Value:123456
Master Code Modification09*PPPPPPRRRRRR#
PPPPPP=New master code
RRRRRR=Repeat the new master code
09*PPPPPPRRRRRR#
PPPPPP=New master code
RRRRRR=Repeat the new master code
Setting Duress PWD15*PPPP#
PPPP=4-digit Code
(0001-9999,default value:0000)
(M4/M8)15*PPPP#
PPPP=4-digit Code
(0001-9999,default value:4321)
Setting Arming PWD17*PPPP#
PPPP=4-digit Code
(0001-9999,default value:1234)
(M4/M8)17*PPPP#
PPPP=4-digit Code
(0001-9999,default value:1234)
Setting Controller Language
PIN / UID Length Range Setting42*m*n#
m= PIN Length Range 4~8
n= UID Length Range 2~8

 

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Suspend tag

Method 1: 

-------------------------------------------------------------------

Method 2: 

Suspend Invalid:10*SSSSS*EEEEE#
SSSSS=Starting card number  
EEEEE=Ending card number

Suspend Invalid:10*SSSSS*EEEEE#
SSSSS=Starting card number  
EEEEE=Ending card number
Delete tag

Method 1: 

-------------------------------------------------------------------

Method 2: 

 

Remove: 10*SSSSS9EEEEE#
SSSSS=starting card number 
EEEEE=ending card number
Remove: 10*SSSSS9EEEEE#
SSSSS=starting card number 
EEEEE=ending card number
Recover the suspended cardsClient->8.User Card Edit->Select user access mode11*SSSSS*EEEEE#
SSSSS=starting card number
EEEEE=ending card number
11*SSSSS*EEEEE#
SSSSS=starting card number
EEEEE=ending card number
Card or PIN (M4/M8)
Modify the PIN with user address, change
the pass mode into Card or PIN
12*UUUUU*PPPP~PPPPPPPP#
UUUUU=User Address
PPPP~PPPPPPPP=4-digit(default)~8-digit code
(Access by Card or PIN)
Card and PIN (M4/M8)
Modify the PIN with user address, change
the pass mode into Card and PIN
13*UUUUU*PPPP~PPPPPPPP#
UUUUU=User Address
PPPP~PPPPPPPP=User Address;
PPPP=4-digit PIN (0000~9999)
Card number modificationClient->8.User Card Edit->User Card Edit -> Card ID16*UUUUU*SSSSSCCCCC#
UUUUU=user address
SSSSS=5 digit site code
CCCCC=5 digit card code
16*UUUUU*SSSSSCCCCC#
UUUUU=user address
SSSSS=5 digit site code
CCCCC=5 digit card code
Add card by presenting19*UUUUU*QQQQQ#
UUUUU=user address 
QQQQQ=Card quantity(00001=Continuously inducting)
(M4/M8 Mode) 19*UUUUU*QQQQQ#
UUUUU=user address
QQQQQ=Card quantity (00001:
for adding a single card or a batch of random numbering cards)
(M6 Mode) - 22*N#
N=0(Delete tag)/N=1(Add tag)
Master Card Setting
(flashing card and pressing # 
to enter program mode,  
leaving program mode 
by flashing card again.)
07*SSSSS*EEEEE#
SSSSS-EEEEE=00000~15999
SSSSS=starting user address 
EEEEE=ending user address
(M4/M8 Mode) 07*SSSSS*EEEEE#
SSSSS-EEEEE(starting user address-ending user address)=00000-00255
Delete all tag29*29*#29*29*#

Invalid Access Trigger Alarm 
(ex: swipe invalid card / 
PIN Code error / 
Time Zone error / 
Door Group error/ 
Anti-passback error)

Auto enable after firmware upgradeEnable 34*002#
Disable 34*000#  (default value)
Enable 34*002#
Disable 34*000# (default value)
Enable/Disable 
Pass Any Cards
36*MW#
M=AR-725-E; W=WG Reader
(0=disable; 1=enable)
Enter program mode->press 0# at the same time
24*032# 

Modify User Capacity / 
Floor / Alias

User Capacity / Floor / Alias
43*0# : 16384 / 64 / 16 (default value)
43*1# : 32768 / 32 / 16
43*2#: X/X/X
Home Series support 
different user capacity,  
721H/757H support 1024 
and 
321H/331H/725H support 3000 users
Enable / Disable
13.56MHz
Enable: 34*000#(default value)
Disable: 34*008#
unique firmware
Enable / Disable
125kHz
Enable: 34*000#(default value)
Disable: 34*016#
unique firmware

 

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Add Single Tag or Random Tags

-------------------------------------------------------------------

 

Enter program mode →

19*UUUUU*00001#

→ Presenting Cards on Controller

(00001: for adding a single card or a batch of random numbering cards) 

Enter program mode →

19*UUUUU*00001#

Presenting Cards on Controller

(00001: for adding a single card or a batch of random numbering cards) 

Add the Sequential Tags

Enter Program Mode → 19*UUUUU*QQQQQ#

→ Presenting First Card to Controller

Enter Program Mode → 19*UUUUU*QQQQQ#

→ Presenting First Card to Controller

Delete Single Tag

 

-------------------------------------------------------------------

Enter Program Mode → 10*SSSSS*EEEEE#
SSSSS= starting user address / EEEEE= ending user address
Enter Program Mode → 10*SSSSS*EEEEE#
SSSSS= starting user address / EEEEE= ending user address

Delete Sequential Tags

(sequential user address)

Enter Program Mode → 10*SSSSS*EEEEE#
SSSSS= starting user address / EEEEE= ending user address
Enter Program Mode → 10*SSSSS*EEEEE#
SSSSS= starting user address / EEEEE= ending user address
Delete all tags

Enter Program Mode →

29*29*#

Enter Program Mode →

29*29*#

 

 

 

 

 

Controller /  Functions

  

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Enroll

Delete

 

  
Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Access Mode Setting

Enter Program Mode → 04*N#
【N=Access Mode,4=M4;8=M8】

Enter Program Mode → 04*N#

【N=Access Mode,4=M4;8=M8】

Enable / Disable Arming Mode

Enable:

-------------------------------------------------------------------

Disable:

present card+NNNN#
NNNN:Arming PWD
U=Enable target unit (0=AR-725-E , 1=WG Reader)

In programming mode : 

  • Arming:Enter Program Mode  →**#
  • Arming:Enter Program Mode →*#

Not in programming mode : 

  • Input Arming PWD(default value :1234)
  • Open door and enable / disable arming in meanwhile:

Normal Access Procedure →  Input 4-digit Arming Code →#

  • Enable / Disable:

→Input 4-digit Arming Code→Present Valid Card

Enabling or Disabling 
each device into 
arming status

 

 

Card+NNNN#*U#
NNNN:Arming PWD
U=Enable target unit (0=AR-725-E , 1=WG Reader)
Enabling all device 
into arming status
Card+NNNN**#
NNNN:Arming PWD
U=Enable target unit (0=AR-725-E , 1=WG Reader)
Arming PWD17*PPPP#
PPPP = Arming PWD
(0001-9999, default value:1234)
(M4/M8)17*PPPP#
PPPP = Arming PWD
(0001-9999, default value:1234)
Arming Delay
Disabling all device 
into arming status
Card+NNNN*9#
NNNN:Arming PWD
U=Enable target unit (0=AR-725-E , 1=WG Reader)

 

Controller /  Functions

          

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Node ID setting

00*NNN*MMM*AAA#
NNN=Node ID,001~254
MMM=AR-725-E Door Number,Range 001~255
AAA=WG Reader Door Number,Range 001~255
Enter Program Mode → 00*NNN# 
【NNN=Controller Node ID 
(Range 001~254),or (Range001~016) 
when connected with AR-716E】
IP Address Setting 
(enable for new IP Address 
while power re-transmission )

 

01*0*CCCCCCCCCCCC#
Default Value:192.168.1.127 
(CCCCCCCCCCCC = 192168001127)
set as 000.000.000.000 for 
IP Address Auto Research (DHCP)
Net Mask IPv4 : 
01*1*255255255000#
Gateway (IPv4) :
 01*2*192168001254#

 

Controller/  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Door Relay Time setting02*U*TTT#
U=Controller Mode
 (0=AR-725-E,1=WG Reader)
TTT=Door Relay Time
000 for Normal Launch On ; 
001~600=1-600 sec;
601~609=0.1~0.9 sec
02*TTT#
TTT=Door Relay Time 000=Normal Launch On
001~600=1sec~600sec
601~609=0.1sec~0.9sec
Alarm Relay Time setting03*TTT#
TTT=Alarm Relay Time;
000 (Normal Launch On)
Time Range:001~600=1~600sec
03*TTT#
TTT=Alarm Relay Time;
000 (Normal Launch On)
Time Range:001~600=1~600sec
Arming Delay Time setting05*TTT#
TTT=the buffer time 
before entering arming mode
001~600=1~600 sec.:
001~255=1~255 sec
05*TTT#
TTT=the buffer time before entering 
arming mode 001~600=1秒~600秒
Alarm Delay Time setting06*TTT#
TTT=the buffer time 
before the alarm is activated
001~600=1~600 sec
06*TTT#
TTT=the buffer time 
before the alarm is activated
001~600=1~600 sec
Arming Pulse Time setting14*TTT#
TTT=Arming output time; 
000=output continuously
001~250=0.1~2.5 sec.
14*TTT#
TTT=Arming output time; 
000=output continuously
001~250=0.1~2.5 sec.
Door Close Delay Time 18*U*TTT#
U=Enable target unit 
(0=AR-725-E , 1=WG Reader)
TTT=Door Close Delay Time 
(001~255sec,default value:15sec)
18*TTT#
TTT=Door Close Delay Time 
(001~255sec,default value:15sec)
Same Tag Reading Interval Time31*TTTT#
TTTT=10~6000 
(Base on 10ms, range from 10 to 6000 
; default value: 1 sec.:0100)
31*TTTT#
TTTT=10~6000 
(Base on 10ms, range from 10 to 6000 ; 
default value: 1 sec.:0100)
Controller Time Clock Setting25*YYMMDDHHmmSS#
YYMMDDHHmmss=
Year / Month / Day / Hour / Min / Sec
25*YYMMDDHHmmSS#
YYMMDDHHmmss=
Year / Month / Day / Hour / Min / Sec
Alarm Setting32*SS*HHMMTT*7123456#
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Holiday Setting35*MMDD*F#
MM:Month;DD:Day ; 
F:0 Delete;F:1 Add

 

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Anti-pass-back (Enable user address)26*SSSSS*EEEEE*P#
SSSSS=Starting User Address;
EEEEE=Ending User Address;
N=0: Enable; N=1: Disable; N=2: Reset
26*SSSSS*EEEEE*P#
SSSSS=Starting User Address;
EEEEE=Ending User Address;
N=0: Enable; N=1: Disable; N=2: Reset
Anti-pass-back (Enable Controller)Enter Program Mode → 20*U*DDD# 
【U= (0=AR-725-E , 1=WG Reader)】
【20* please refer to Function Default Value】
Enter Program Mode → 20*DDD# 
【128=anti pass back function 
(0=disable;1=enable);
064=set as Exit / Entry
(0=Exit;1=Entry)】

 

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Lift control setting: 
single floor(M4/M8)
27*UUUUU*LL#
UUUUU=user address;
LL:Floor number(01~64 floor)
(M4/M8 Mode)27*UUUUU*FF#
UUUUU=User Address; 
FF=Floor (01~32 floor)
Lift control setting: 
multi-floor(M4/M8) 
(Details please refer to 
the manual of each Controller)
21*UUUUU*G*LLLLLLLL#
UUUUU=user address;G=4 sets of lift control(0~3);
LLLLLLLL=8 assigned floor (F=0: Disable, 1: Enable)
21*UUUUU*S*FFFFFFFF#
UUUUU=User Address, 
S=4 sets of lift control (0~3);
FFFFFFFF=8 assigned floor
(F=0: Disable, 1: Enable)
AR-401-IO-0016R Lift Relay Activated TM (M4/M8) 23*MMM*TTT#
MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec
23*MMM*TTT#
MMM=site number, 
TTT= relay time: 
000~600=1~600 sec
Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

RS485 port function setting 
(Needs to be restarted 
after setting)

37*AB#
A=0:AR401RO
1:Host (Default Value)
2:LED Panel
3:Printer 

----------------------------------

B=0: 9600 (Default Value)

  1: 19200
2: 38400
 3: 57600

Change WG bits 
output format
41*n#
n:0=WG26
n:1=WG34
Enable the RF 
after door sensor 
closed to GND
Auto enable after firmware upgradeAuto enable after firmware upgrade

Enable: 34*001#
Disable: 34*000# (Default Value)

Turn off all sounds of beeper 

Enable:34*001# ( Turn off )
Disable:  34*000# (Default Value)

Enable: 34*001#
Disable: 34*000# (Default Value)

Enable/Disable 
keypad lock
press *# simultaneously
(do not enter program mode)
Enable:Keyboard Lock
Disable:Keyboard Unlock
Enable :34*064#
Disable: 34*000# (Default Value)
press *# simultaneously
(do not enter program mode)
Enable:Keyboard Lock
Disable:Keyboard Unlock
Enable/Disable“#”
as Door Bell
 ( Use Alarm output 
as Door Bell )
Enable/Disable“#”as Door Bell 
0: disable (default value) / 1: enable
Enable : 34*004#
Disable: 34*000# (Default Value)
Enable : 28*128#
Disable: 34*000# (Default Value)

 

 

Controller /  Functions

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Enable / Disable 
Auto Open Time Zone 
(open door need to 
present first valid card)
Enable : 20*U*DDD# 
Disable : 20*U*000# 
Enable : 20*U*DDD# 
Disable : 20*U*000# 
Enable / Disable 
Auto Open Time Zone 
Open Door without 
Present First Valid Card
Enable : 24*U*128#
Disable : 24*U*000#
Enable : 24*128#
Disable : 24*000#
Auto-open time zone setting08*MW*NN*HHMMhhmm*7123456H#
M=AR-725-E;W=WG Reader 
(0:disable,1:enable)
NN=00~15 (time zone)
HHMM=begin time ; hhmm=end time 
(ex:08301200=08:30 to 12:00)
7123456H:Sun,Mon,Tue,Wen,Thu,Fri,Sat,Holiday
(0:disable,1:enable)
 08*NN*HHMMhhmm*7654321H#
NN=00~15 (time zone)
HHMM=begin time ; hhmm=end time 
(ex:08301200=08:30 to 12:00)
7123456H:Sun,Mon,Tue,Wen,Thu,Fri,Sat,Holiday
(0:disable,1:enable)

 

 

Controller /  Functions

 

Software

E Series Controller with LCD Screen

E Series Controller with Keypad

H Series Controller

Exit Program Modepress*until LCD shows 6. Quit → press # to exit*#*#
Exit Program Mode and 
enter arming mode(M4/M8)
**#**#

 

 

Browsing Records
Go Top