Various Application Scenarios and Comparisons of Multi-door Interlocking Systems
2024-01-31
No. A001035-EN

Serial NO. : A001035

Date of Editing : 2024-01-31

 

1. Comparison of Functions in Multi-door Interlocking for AR-401-IO-1709R & AR-401-IO-0808R:

ProductModule I/O (17 Optical Isolation Input/9 Relay Output)
AR-401-IO-1709R
ProgrammableLogic Controller(WEB PLC)
AR-401-IO-0808R
PIC
Support for the number of interlocked doors2~8 doors2~64 doors
701ClientSQL dynamic graphical control function   
Flexibly adjust the interlocking relationship between doors
Alarm action output time

3 sec./6 sec./9 sec./Continues until door closes(Latch)

The parameters can be programmed and configured through the WEB PLC.
Door position detection time for opening timeoutThe parameters can be programmed and configured through the WEB PLC.
Electric lock release time3 sec./6 sec./9 sec./15 sec.The parameters can be programmed and configured through the WEB PLC.
Firmware version

4 Doors Interlock with Fire Alarm Auto Release All Doors Open : 401RO8DI16_V0207_210910 DOOR_INTERLOCK_4.ISP

Download

(Independent alarm output point)

Standard Firmware : APX727i3___V0505 231227 8i8o PLC 16bit TMR Pulse Queue.STM

Download

(Standard firmware, programmable settings regardless of the number of doors)

8 Doors Interlock with Fire Alarm Auto Release All Doors Open : 401RO8DI16_V0207_210910 DOOR_INTERLOCK_8.ISP

Download

(Single alarm output point)

 

2.AR-401-IO-0808R Application Examples and Configuration Guide:

è[ WEB PLC ] 4 Doors Interlock

è[ WEB PLC ] Cleanroom with Five Rooms and Interlocking Multi Doors

 

 

3.AR-401-IO-1709R Application Examples and Configuration Guide:

èCloud Monitor of Escape Door in Building

èOne-way multi door interlocking solution AR-401-IO-1709R