Modify custom settings for controllers' LCD shift codes and monthly report shift codes.
2021-01-12
No. H03217007-EN

Serial NO : H03217007

Date of Editing : 2017-01-19

Index:

1.Precautions

2.Modification of LCD shift codes

3.Restore default values

4.Modify the shift display in the monthly report of 701ClientSQL.

5.Checklist for Inspection

 

 

1.Precautions 

1.The attendance shift will be displayed in two places: the monthly report of 701ClientSQL and the LCD of the time clock.

2.You can modify the name content with a maximum of three Chinese characters.

3.After issuing the command, the controller needs to be powered off and on again to complete the modification.

 

 

2.Modification of LCD shift codes 

Step1. Confirm the Controller is inline

Step2. Select COM port or TCP/IP address in Commview

Default value command:

20 0B FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF... (64 units of FF)

8 bytes make up one group, the last 2 bytes are reserved (no effect).

► Use Big5 code lookup system.

Example: Change the name to "Entry" and "Exit".

20 0B 20 A4 4A B3 F5 20 FF FF 20 A5 58 B3 F5 20 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF  

         Entry  Space  Exit

FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF

After entering, click "Send", and you will receive a response upon successful modification.

 

Change "Work" and "Off" to "Class" and "Break," and leave the other shifts blank.

20 0B 20 A4 57 BD D2 20 FF FF 20 A4 55 BD D2 20 FF FF 202020202020202020202020202020202020202020202020202020202020202020202020202020202020202020202020

After powering off and on again, the screen of the time clock will display as follows.

 

 

3.Restore default values.

Method 1. Reset All Duty Name via Commview

Step1. Confirm the Controller is inline

Step2. Select COM port or TCP/IP address in Commview

Step3. Send the command

(1) 20 0B FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF (64 units of FF)

(2) 20 09 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF (64 units of FF)

Detail operation please refer to >>> Commview Manual

 

 

Method 2. Reset All Duty Name via Pressing Reset Button

Step1. Update the controller firmware

Step2. Press reset button directly and waiting for the flashing of red LED

 

Detail operation please refer to >>> UDP Updater Manual

All series controller’s firmware please download at >>> Firmware Download

 

 

Method 3. Reset Single Duty Name via Commview

Step1. Confirm the Controller is inline

Step2. Select COM port or TCP/IP address in Commview

Step3. Send the Command as below (modification please refer to your requirement)

20 0B 44 75 74 79 3A 30 FF FF 44 75 74 79 3A 46 FF FF 4F 55 54 3A 20 30 FF FF 4F 55 54 3A 20 46 FF FF 42 52 4B 3A 20 30 FF FF 42 52 4B 3A 20 46 FF FF 47 4F 20 4F 55 54 FF FF 52 45 54 55 52 4E FF FF

Press F1 once - Duty:044 75 74 79 3A 30
Press F2 once - Duty:F44 75 74 79 3A 46
Press F3 once - OUT:04F 55 54 3A 20 30
Press F4 once - OUT:F4F 55 54 3A 20 46
Press F1 twice - BRK:042 52 4B 3A 20 30
Press F2 twice - BRK:F42 52 4B 3A 20 46
Press F3 twice - GO OUT47 4F 20 4F 55 54
Press F4 twice - RETURN52 45 54 55 52 4E FF FF

 

4.Modify the shift display in the monthly report of 701ClientSQL.

Note: Although the hardware modification is successful, the software will still display the default shifts. 

If you need the record file to display "Entry" and "Exit," you can convert the shift names to the format used in the time clock. Specify "Entry" for the start of work and "Exit" for the end of work, and finally export it as a text file.

 

 

5.Checklist for Inspection

ConfirmationItemCheck Content
1.Confirm the connection between the controller and the computer.
2.Select the communication port (COM or TCP/IP) and station number for the controller.
3.In CommView, modify the name content of the shift command with a maximum of three Chinese characters.
4.After issuing the command, the controller needs to be powered off and on again.
5.Modify the shift names displayed in the monthly report of 701ClientSQL.